Skip to Main Content
Spotfire Ideas Portal
ADD A NEW IDEA

Spotfire Statistica

Showing 218 of 4339

The server setting is not changing with DSN change, because all the options in Tools>>Options get stored per machine/per user

Our organization use 2 different boxes ( 1 for Test and another one for Production. Soon we will have another server for Training as well). Currently, the server setting is not changing with DSN changes, because all the options in Tools>>Opt...
about 6 years ago in Spotfire Statistica 2 Future Consideration

support for JDBC data source connection

Please support connections to data sources through JDBC driver. Even though most databases that can be connected through JDBC, also have ODBC driver available, and there is also ODBC-JDBC bridges out there for user to consider, it might still be g...
about 6 years ago in Spotfire Statistica 1 Future Consideration

Ability to increase header size of DE Input for specifically for Characteristic/Label

It would be helpful to \increase the characteristic/label header length alone (so it doesn't warp to 2 lines, see screenshot) without increasing the input area without having to increase it globally for all DES via application settings.
about 6 years ago in Spotfire Statistica 0 Future Consideration

Laney P Prime Chart

The Laney P Prime Chart offers a number of benefits over a standard P chart – corrects for varying sample size, over dispersion and other potential failures. This chart is very important in the pharmaceutical industry. While P (and other statistic...
about 3 years ago in Spotfire Statistica 0 Planning to implement

Import multiple files from a folder into statistica as a single merged file

We are trying to load several thousand .txt files to combine and then do text mining. Is it possible to import 'all' in some way rather than import each txt file one at a time? Otherwise it would take a long time to do multiple import nodes and th...
over 6 years ago in Spotfire Statistica 0 Future Consideration

Customisation of Whiskers

Dear Tibco, In STATISTICA I ran into the problem of not being able to individually change the positive and negative whiskers/spreads on the graphs. Specifically, I needed to delete the negative whiskers on my graphs upon request, however, since th...
about 3 years ago in Spotfire Statistica 0 Unlikely to implement

detect if a model is going to generate x number of lines in Java and then split into smaller predict functions

There is a limitation with Java that a method cannot have more than 64K btyes information (https://stackoverflow.com/questions/2407912/code-too-large-compilation-error-in-java). Many Random Forest and Boosted Tree models exceed this limit when dep...
over 6 years ago in Spotfire Statistica 1 Future Consideration

Allow a greater number of variables in the Factor Analysis and Principal Components. (max is 4092)

The problem, as shows the image attached, is that Statistica has a maximum number of variables. Others softwares can run the same analysis with more than 4092 variables. Please add a greater number of variables to this analysis. Regards, Caue Al...
over 6 years ago in Spotfire Statistica 0 Future Consideration

Access MAS Alarms through a REST Web API

Reference STAT-5867 Alarms acknowledged within the Statistica system have a use, but in some cases alarms are investigated and elevated to real process deviations in our facility. We would like to automate the process of sending alarm information ...
over 6 years ago in Spotfire Statistica 0 Future Consideration

Default Settings for new IQC analysis configurations in Enterprise Manager, especially Runs Tests

The customer uses IQC analysis configuration, and he usually wants to activate specific rules, only.
over 6 years ago in Spotfire Statistica 0 Future Consideration