Skip to Main Content
Spotfire Ideas Portal
ADD A NEW IDEA

Data Access

Showing 482

One shared server connector cache

In cases of multiple web servers, a data connection can't be cached between web servers. Information links appear to allow caching for all users.
about 6 years ago in Spotfire / Data Access 0 Future Consideration

Connector drivers should only need to be installed once in a Spotfire topology

Today each driver needs to be manually deployed on each web node server.
about 6 years ago in Spotfire / Data Access 0 Future Consideration

Scrape tables from webpages

Create a new Data Source type for "Website" that will scrape data from within any tables. I believe this should be fairly simple by parsing the html <table> tags.
about 6 years ago in Spotfire / Data Access 0 Future Consideration

Add filter to the join interface to limit the rows of one of the column elements in the join table

I recently wanted to join two tables via information links. However, what I really needed was a subset of the rows that existed in the data table. Joining the entire data table created a resulting table that was too large to be practical and did n...
about 6 years ago in Spotfire / Data Access / Information Services 0 Future Consideration

Ability to have a base Info Link and that can be easily replaced and then others would automatically update

Hi, I often have one information link that is the full data set and others that are a 'Save as" version with some filter applied. It would be great to be able to update the base information link, and have the "daughter info links" update too. Also...
about 6 years ago in Spotfire / Information Services 0 Future Consideration

Add supported functions for in-db connections to Redshift

The supported functions for in-db connections to Redshift (https://docs.tibco.com/pub/sfire-analyst/7.12.0/doc/html/en-US/TIB_sfire-analyst_UsersGuide/connectors/amazon-redshift/redshift_supported_functions.htm) are insufficient to perform any use...
about 6 years ago in Spotfire / Data Access 0 Future Consideration

When refresh data table, how to modify only some of the source information

When Edit> Data Table Properties> Refresh Data, I want to fix only one device or one content. It seems to be a lot of time loss because I have to create all new. I want to refresh the data table by modifying only some of the source information.
over 6 years ago in Spotfire / Data Access 2 Already exists

a wizard to convert an SQL-based data table to an infolink and datasource.

we have a nr of data tables based on a SQL query. It would be great if there was a wizard to convert such an SQL-based data table to an infolink and datasource. We develop often 1:1 on the database, and once the analysis is good enough we go throu...
over 6 years ago in Spotfire / Information Services 1 Future Consideration

Oracle Data Connection - Limit available tables in database to user defined schema/object names

Even with a low privilege database user, objects in PUBLIC schema are still visible. The ability to limit the visibility of specific schema, and to limit the objects visible by name (pattern matching) would be useful
over 6 years ago in Spotfire / Data Access 1 Will not implement

Stop adding new empty row or semicolon in UI when editing fields

Trim ending empty rows and/or semicolon from Connection Initializer, Opens Session Command and Close session command. And, stop automatically adding any new empty row or semicolon in UI when editing any of the fields.
over 6 years ago in Spotfire / Data Access / Information Services 0 Future Consideration